1 EV Chamber with battery simulation system, capable of conducting load testing on new energy high-voltage components
1 EV Chamber with battery simulation system, capable of conducting load testing on new energy high-voltage components
Detection capability
Electromagnetic emission testing |
Test items |
Test scope |
Reference standards |
Conducted emission voltage method |
9kHz-200MHz |
CISPR 25、GB/T 18655 |
|
Conducted emission current method |
9kHz-400MHz |
CISPR 25、GB/T 18655 |
|
Radiation emission |
8.3kHz-6GHz |
CISPR 25、GB/T 18655 |
|
Magnetic field near-field emission |
1Hz-400MHz |
MIL-STD-461G |
|
Magnetic field far-field emission |
9KHz-30MHz |
GB/T 18387 |
|
Far-field emission of electric field |
9KHz-30MHz |
GB/T 18387 |
|
Voltage transient emission test |
快脉冲、慢脉冲 |
ISO 7637-2 |
|
Voltage transient emission test along high-voltage power lines |
60V DC~1500V DC |
ISO 7637-4 |
|
harmonic current |
3*480V/3*690V AC;1000V DC |
IEC 61000-3-2、GB/T 17625.1 |
|
Voltage flicker |
3*480V/3*690V AC;1000V DC |
IEC 61000-3-3、GB/T 17625.2 |
Electromagnetic immunity test |
Test items |
Test scope |
Reference standards |
Radiation Immunity - ALSE |
80MHz-6GHz |
ISO 11452-2、GB/T 33014.2 |
|
High current injection BCI |
0.1MHz-400MHz |
ISO 11452-4、GB/T 33014.4 |
|
Low frequency magnetic field anti-interference MFI |
DC-1MHz |
ISO 11452-8、GB/T 33014.8 |
|
Handheld transmitter immunity PTI |
26MHz-6GHz |
ISO 11452-9、GB/T 33014.9 |
|
Electrostatic discharge ESD |
±30kV |
ISO 10605、GB/T 19951 |
|
Transient immunity along power lines - CI |
Pulse 1 ~ 7 |
ISO 7637-2、GB/T 21437.2 |
|
Transient immunity except for power lines - CI |
ICC、CCC、DCC |
ISO 7637-3、GB/T 21437.3 |
|
Surge (impact) anti-interference |
±7kV,AC, 1000V DC, 125A |
IEC 61000-4-5、GB/T 17626.5 |
|
Electric fast transient pulse group EFT |
±5.5kV,AC, 1000V DC, 125A |
IEC 61000-4-4、GB/T 17626.5 |
|
Transient immunity test for high-voltage power lines |
PulseA、B |
ISO 7637-4 |